# NSN 5945-01-344-2504: Relay, Electromagnetic

NSN 5945-01-344-2504 (also written 5945013442504; NIIN 01-344-2504) is a relay, electromagnetic in Federal Supply Class 5945, Relays and Solenoids. 3 manufacturer part numbers from 3 suppliers are on record. No purchases are on record yet.

## Identification

- NSN: 5945-01-344-2504 (5945013442504)
- NIIN: 01-344-2504 (013442504)
- Item name: RELAY,ELECTROMAGNETIC
- Federal Supply Class: [FSC 5945 Relays and Solenoids](https://nsnexplorer.com/fsc/5945/)
- Federal Supply Group: [FSG 59](https://nsnexplorer.com/group/59/)
- Acquisition method suffix code: AMSC Z: a commercial, nondevelopmental or off-the-shelf item. (observed 2026-10-10)
- Acquisition method code: 3

## Characteristics

| Code | Requirement | Reply |
| --- | --- | --- |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 1.718 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES MINIMUM 1.396 AND INCHES MAXIMUM 1.446 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 0.525 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 1.125 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.150 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJSS | FREQUENCY IN HERTZ | MINIMUM 50.0 AND MAXIMUM 400.0 |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY SLOTTED HOLE 2 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | CUBIC INCHES 1.051 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY IN-LINE |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 2 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES AC 30.0 |
| CRXH | TIME DELAY | FIXED OPERATE TIME SECONDS NOMINAL 0.015 |
| CRXH | TIME DELAY | FIXED RELEASE TIME SECONDS NOMINAL 0.05 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS AC 25 DEG CELSIUS 115.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES AC 8.0 AND AMPERES DC 8.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | MOTOR LOAD AMPERES AC 4.0 AND AMPERES DC 4.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD AMPERES AC 2.0 AND AMPERES DC 2.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| MATT | MATERIAL | CONTACT SILVER |
| PMLC | PRECIOUS MATERIAL AND LOCATION | SILVER TER-INALS AND GOLD SURFACE |
| PRMT | PRECIOUS MATERIAL | GOLD AND SILVER |
| SFTT | SURFACE TREATMENT | CONTACT GOLD |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS WIRE HOOK 8 |

## Part numbers

| Part number | CAGE | Supplier | Source |
| --- | --- | --- | --- |
| FCA-210-CX9 | 00213 | STRUTHERS-DUNN INC. | [flis](https://www.dla.mil/Portals/104/Documents/InformationOperations/LogisticsInformationServices/FOIA/PUBLOG/) |
| FCA-210-CX9 | 58614 | TE CONNECTIVITY CORPORATION | [flis](https://www.dla.mil/Portals/104/Documents/InformationOperations/LogisticsInformationServices/FOIA/PUBLOG/) |
| FCA210CX9 | 78290 | STRUTHERS-DUNN INC | [flis](https://www.dla.mil/Portals/104/Documents/InformationOperations/LogisticsInformationServices/FOIA/PUBLOG/) |

## Sources

- DLA DIBBS RFQs for this NSN: https://www.dibbs.bsm.dla.mil/RFQ/RFQNsn.aspx?value=5945013442504&category=nsn
- DLA DIBBS awards for this NSN: https://www.dibbs.bsm.dla.mil/Awards/AwdRecs.aspx?category=awdnsn&TypeSrch=cq&Value=5945013442504
- AMSC record: https://www.dla.mil/Portals/104/Documents/InformationOperations/LogisticsInformationServices/FOIA/PUBLOG/
- All data is public U.S. government data; every row above links to its source record where one exists.

Canonical page: https://nsnexplorer.com/nsn/5945-01-344-2504/
JSON: https://nsnexplorer.com/api/nsn/5945-01-344-2504.json